RLYM-1EU

Specification Relay- Hardwire Interlink Only

Mains Powered 5 Year Warranty Kitemark Hardwired

Product description

With an ultra slim design, our specification hardwired relay will extend any Smart RF network with third party systems e.g. fire doors or telecare systems.

Options to differentiate fire and CO alarm signals and activate relay contact independently from the other. Wireless interlink version also available.

  • Mains powered with battery back-up
  • Connect fire and CO alarms to external devices such as fire doors and other Telecare systems
  • Ultra slim design with “pulse signal” or a “continuous switched signal” options
  • Hardwire interlink to a mains powered Specification smoke (SM-SN-1) or heat alarm (HM-SN-1)
  • Wireless only relay also available (see WRLYM-1EU)
MoreLess

With an ultra slim design, our specification hardwired relay will extend any Smart RF network with third party systems e.g. fire doors or telecare systems.

Options to differentiate fire and CO alarm signals and activate relay contact independently from the other. Wireless interlink version also available.

Key Benefits and Features

Where to install your CO alarm

Product manual

Product manual

Click the icon to download the product manual

Datasheet

Datasheet

Click the icon to download the product datasheet

Compliant and Certified For Safety

What's in the box?

Reviews from our customers

Related FAQs

Yes, you can connect a FireAngel relay to external devices e.g. fire doors, sprinklers and other Telecare systems. You can also connect relays with FireAngel Smoke, Heat and CO Alarms.

You have the option to differentiate between smoke, heat & CO alarm signals and activate an appropriate relay contact independently from the other. Please refer to the manual for full details.

You should check that the battery back‑up switch is on. The green unit power LED should be illuminated. Refer to the manual for full installation guidance.

Whilst BS 5839‑6 has previously been split into six varying Grades, each outlining the level of protection appropriate for certain properties and their corresponding levels of risk, the new update has altered the six sections, removing Grade B and Grade E, whilst Grade D and Grade F have been split into Grade D1 / Grade D2 and Grade F1 / Grade F2 respectively. Grade C has been revised and its recommendations expanded.
The 2019 grading system is as follows:
Grade A
Separate detectors, sounders and central control and indicating equipment with back-up power supply that conforms to British Standards BS EN 54.
Grade C
Separate detectors and sounders that are mains powered with back-up power supply and central control equipment.
Grade D1
A system of one or more mains powered detectors, each with a tamper‑proof standby supply consisting of a battery or batteries (such as FireAngel’s SM-SN-1 and HM-SN-1 alarm).
Grade D2
A system of one or more mains-powered detectors, each with an integral standby supply consisting of a user‑replaceable battery or batteries. (such as FireAngel’s SW1-PF-T and HW1-PF-T alarm).
Grade F1
A system of one or more battery-powered detectors powered by a tamper‑proof primary battery or batteries (such as FireAngel’s ST-622T, ST-750 alarm).
Grade F2
A system of one or more battery-powered detectors powered by a user‑replaceable primary battery or batteries. (such as FireAngel’s SB1-T alarm).
Please note: Grades B and E are no longer defined in BS 5839-6:2019.
See all faqs

Extend Your Protection

Protecting your properties and customers is easier than ever with our range of smoke, heat, and carbon monoxide alarms. To ensure complete coverage, it’s essential to make sure you’re installing best practice and being compliant with your regional fire safety laws.

For even greater peace of mind, consider upgrading to our Specification Range. These smart alarms offer wireless interlinking, meaning if one alarm is triggered, all alarms in the home will sound. Plus, they can be monitored through our FireAngel Connected smartphone app, whether you’re at home or away.

Get in touch with our Specification Managers today to see how our FireAngel Connected solution can support you and your tenants.

social-housing
Specification 10 Year Kitchen Heat Alarm, Battery Powered image

FS1226-T

Specification 10 Year Kitchen Heat Alarm, Battery Powered

Designed with installers in mind, this compliant, flexible, easy to fit range delivers advanced...

Specification Carbon Monoxide Alarm, 10 Year Sealed Battery  image

FS1326-T

Specification Carbon Monoxide Alarm, 10 Year Sealed Battery

Designed with installers in mind, this compliant, flexible, easy to fit Specification range...

Specification Smart RF Radio Module image

FS1521W2-T

Specification Smart RF Radio Module

Easily upgrade your compatible Specification devices with the Smart RF module to create a wireless...

Specification Wireless Alarm Control Unit image

FS1524W2-T

Specification Wireless Alarm Control Unit

Our alarm control unit allows individuals to test interlinked Specification alarms, without the...

Specification Combined Strobe and Pad image

FS1552W2-T

Specification Combined Strobe and Pad

Assisted living solution for enhanced home safety, this device has been designed to provide an...

Specification Connected Wireless Gateway image

FS1580W2-T

Specification Connected Wireless Gateway

Designed for private properties, this compliant and easy to fit Gateway allows remote monitoring of...

Get in touch

Want to discuss how FireAngel can help you? Fill in a short form and book a call to speak to our dedicated trade support team.

Related Support Posts

Awaab’s Law: A guide for social landlords... image

Compliance

Awaab’s Law: A guide for social landlords...

Are you ready for Awaab’s Law and the new legal timeframes that will reshape how social landlords...

Why is it important to have a digital... image

Private landlords

Why is it important to have a digital...

Digital display CO alarms provide landlords, housing providers, and tradespeople with clear data,...

Clocks go back: Portfolio-wide ‘test... image

Compliance

Clocks go back: Portfolio-wide ‘test...

Use the October clock change as a strategic prompt to simplify fire and CO safety management and...

How to protect holiday lets from fire and CO... image

Fire Safety

How to protect holiday lets from fire and CO...

Keep your holiday lets safe during autumn and winter by understanding fire and CO risks, conducting...

Comprehensive guide to fire alarm... image

New Build

Comprehensive guide to fire alarm...

Meeting fire alarm requirements in new build homes is a non-negotiable part of UK construction....

Comprehensive trade guide: multi-sensor fire... image

Fire Safety

Comprehensive trade guide: multi-sensor fire...

Multi-sensor alarms are a forward-thinking option that offers a smarter, more reliable, and...